If your air compressor circuit breaker trips when you start, or if the lights dim or fluctuate for a few seconds each time you turn it on, it means you have a high energy consumption. This high power consumption could exceed the capacity of the circuit breaker and cause a trip. A dirty air filter is one of the reasons why circuit breakers trip on the air compressor. The air filter prevents dirt from entering the air pump.
Dirt on the air pump can cause serious problems and may require costly repairs. If you notice that your air conditioner is tripping the switch when it's too hot outside, a dirty air filter may be to blame. Dirty filters can reduce airflow and cause air conditioning units to overheat, causing a shot I tried to find the specs and a photo of your Devilbiss Prfbc5525vp air compressor online with no luck, so I'm shooting in the dark here. If the air pressure remains in the tank after the compressor has stopped and discharged, it is likely to work well.
If it is a fuse in the circuit rather than a circuit breaker, when attempting to restart, the compressor blows the fuse. If you notice that the circuit breaker on your air compressor is cutting off the electricity supply, you should check the following;. I have a dewalt 30hp compressor, it fills up well, then when I start using it and it starts to refill the breaker power comes out and it won't allow me to use it again because the air doesn't refill, please help. The pressure switch activates to pass and allows the compressor to start and operate until the compressor tank pressure has reached its cut-off pressure.
Having your compressor pour air again after trying to start suggests to me that it is your pressure switch that is failing, and when you try to start the air compressor, it short-circuits the power, blows the circuit breaker and causes the pressure switch to turn off again. What happens is that the air compressor consumes more energy than the required limit, which is not possible for a circuit breaker that causes a trip. As a comment here, tell me how you are receiving power to your air compressor and the amperage of the circuit breaker that your air compressor is connected to. About 8 months later, the compressor broke down, but instead of replacing it with the original 5 hp compressor, I replaced it with the 7 hp compressor.
I have the same problem. I have the same compressor. Have you ever found out what it's all about? I turn it on and it turns on for a second and then I set off the switch if you know what it is, can you bring it back to me? Thank you. They also make it difficult for air conditioners to operate efficiently in colder temperatures, so you may notice that your air conditioner doesn't cool your home like before.
I suspect that the demand for engine inrush to the compressor exceeds the generator output capacity. By that, I mean that no extension cable is used, and no other appliance that draws power from the same circuit that the air compressor is in.